Enter the room size and a few details, and this free mini split sizing calculator estimates the cooling capacity one indoor head needs. It uses the ENERGY STAR room air conditioner sizing chart, with its adjustments for shade, sun, people and kitchens. Some people call it a mini split BTU calculator or a mini split size calculator; the idea is the same.
Calculate the BTU Your Room Needs
Based on the ENERGY STAR room air conditioner sizing chart and its adjustments for shade, sun, people and kitchens. It estimates cooling for one room or zone. It is not a Manual J load calculation. Nothing you type leaves this page.
How the Mini Split Sizing Calculator Works
The starting point is the ENERGY STAR sizing chart for room air conditioners. It lists the cooling capacity a room needs by floor area, and it assumes an 8-foot ceiling.
| Room area (sq ft) | Capacity (BTU per hour) |
|---|---|
| 100 up to 150 | 5,000 |
| 150 up to 250 | 6,000 |
| 250 up to 300 | 7,000 |
| 300 up to 350 | 8,000 |
| 350 up to 400 | 9,000 |
| 400 up to 450 | 10,000 |
| 450 up to 550 | 12,000 |
| 550 up to 700 | 14,000 |
| 700 up to 1,000 | 18,000 |
| 1,000 up to 1,200 | 21,000 |
| 1,200 up to 1,400 | 23,000 |
| 1,400 up to 1,500 | 24,000 |
| 1,500 up to 2,000 | 30,000 |
| 2,000 up to 2,500 | 34,000 |
Then the calculator applies the ENERGY STAR adjustments:
- Heavily shaded room: reduce capacity by 10 percent.
- Very sunny room: increase capacity by 10 percent.
- More than two people: add 600 BTU for each extra person who regularly uses the room.
- Kitchen: add 4,000 BTU.
One step is our own estimate, not part of the ENERGY STAR chart. For ceilings above 8 feet, the calculator scales the chart figure by the extra height. A 10-foot ceiling adds a quarter to the base figure.
Finally, it rounds up to the nearest common indoor head size, such as 9,000, 12,000 or 18,000 BTU. Exact sizes vary by brand and product line.

When to Size Differently
The chart sizes cooling for one room. Real homes have more going on, so treat the result as a starting point for a conversation with an installer.
- Cold climates. Heating often decides the size. Check the heat output at 5°F on the spec sheet, not just the rated capacity. ENERGY STAR’s cold climate heat pumps must keep at least 70 percent of their 47°F heating capacity at 5°F.
- Open plans and several rooms. One head serves the space it can “see”. Closed rooms off a hallway usually need their own head or a ducted unit.
- Large or unusual spaces. Above 2,500 square feet, or with lots of glass, poor insulation or high ceilings, ask for a Manual J load calculation.
- Oversizing. A unit that is too big cycles on and off more and removes less humidity. Bigger is not safer.
Worked Examples
These examples use the calculator’s own method.
| Room | Inputs | Estimate | Common head size |
|---|---|---|---|
| Bedroom, 12 by 12 ft | 144 sq ft, normal sun, 2 people | 5,000 BTU | 6,000 BTU |
| Living room, 20 by 25 ft | 500 sq ft, very sunny | 13,200 BTU | 15,000 BTU |
| Kitchen, 15 by 15 ft | 225 sq ft, kitchen | 10,000 BTU | 12,000 BTU |
| Bonus room, 12 by 12 ft | 10 ft ceiling, shaded, 4 people | About 6,800 BTU | 9,000 BTU |
Related Guides
Before you buy, read our honest list of the disadvantages of mini split systems. If your unit already runs and shows a DF code in winter, see what DF means on a mini split. For the original chart, see the ENERGY STAR room air conditioner guide.
Sizing for a whole floor instead of one room? Our ducted mini split guide explains when one concealed unit with ducts makes more sense than several wall heads.
Frequently Asked Questions
What size mini split do I need for a 12 by 12 room?
A 144 square foot room falls in the ENERGY STAR 100 to 150 square foot band, which is 5,000 BTU. Most buyers choose the smallest common head, often 6,000 or 9,000 BTU, after the adjustments.
Can I use this calculator for heating?
Use it as a cooling estimate. For heating, compare the unit’s heat output at your coldest winter temperature with the heat the room loses, which a load calculation measures.
Is a bigger mini split better?
No. An oversized unit short cycles, removes less moisture and can feel clammy. Size to the load, then round up only to the next available size.
Does this replace a Manual J calculation?
No. It is a quick estimate from a published chart. A Manual J load calculation looks at insulation, windows, air leakage and climate in detail.